Want to know more?
Ask the team at Texcel how we can automate, inform, and empower your teams with our services.
The Nor130 series of SLM fulfil the following Sound Level Meter and 1/1&1/3 octave filter standards: IEC 60651, IEC 60804, IEC 61672, IEC 61260, ANSI S1.4, ANSI S1.11, ANSI S1.43, DIN45657.
Simultaneous measurement of SPL, Leq, LMax, LMin, LE and LPeak (plus the Tmax5 for Germany only).
Time weighting functions: Fast, Slow and Impulse.
Spectral weighting functions: Simultaneously measurement of A and C or Z-weighting. Additionally the 1/1 octave real time filters covering all bands from 8 Hz to 16K Hz (option 1) or 1/3-octave covering all bands from 6,3Hz to 20kHz (option 4).
Statistical calculations: 7 fixed percentiles L1%, L5%, L10%, L50%, L90%, L95%, and L99% plus one user defined value (f.ex. L0.1%). The statistical calculation is performed in real time within each frequency band if the filter option 1 is installed.
One range covering 120dB without any range adjustments.
Self noise measured with microphone: 17dBA (25dBA for Nor132)
Maximum RMS level: 137dBA
Maximum Peak level: 140dB PeakC
Levels up to 174dB can be measured by use of a suitable 1/4” microphone
Battery: 4 cells, IEC LR6, AA-sized, Alkaline batteries are recommended (e.g. Duracell Ultra M3). AA-sized NiCd or NiMH rechargeable batteries may be used, but must be charged outside the instrument. Battery voltage and time on battery since last change of bat-teries are indicated.
Typical battery life time (Duracell Ultra M3): 8 – 12 hours.
External dc: 11 – 16 volt. Power consumption approximately 1.2 watt dependent on selected modes of operation. External DC source should have source-impedance less than 1 ohm and be able to supply at least 300 mA. The mains adaptor Nor340 is recommended for use with the instrument. If the external supply falls below 9 V, the instrument will use the internal batteries if available. If the instrument has switched off due to loss of power or insufficient supply voltage, the instrument will automatically switch on after reapplying the external DC supply.
Display: The display is a monochrome, trans-reflective LCD graphical display with 160×240 pixels (W×H) with automatic temperature compensation for contrast and viewing angle. Pressing the light key illuminates the display. The light switches off automatically 2 minutes after the last operation of any key.
The bar graph display covers 80 dB, which may be scrolled in 10 dB steps to cover the total range.
Data storage/Data transfer: Measured data is stored in the internal memory of the sound level meter. The memory is of the “flash” type retaining the information without battery supply. Approximately 5 Mbyte is available for the data storage. This corresponds 10 000 measurements for sound level meters without octave analysis and up to 2 500 for sound level meters with octave analysis. Data transfer via USB 2.0 interface.
Input connector: TNC connector for Norsonic microphone systems.
Preamplifier: Nor1207 IEPE.
Polarisation voltage: 0 V (pre-polarized)
Supply current: 3mA
Supply voltage: 24V
Input impedance: > 100 kohm, <650 pF
Measurement range: 0.3 mV to 7 V (RMS) in one range corresponding to –10 dB to 137 dB with a microphone sensitivity of 50 mV/Pa. The maximum peak value ±10 V corresponds to 140 dB.
Microphone: Nor1228
Analogue output The analogue output is a reproduction of the digitized input signal from the microphone (or input connector) obtained by a digital to analogue converter.
Output voltage: Full scale on the display corresponds to 100 mV.
Output impedance: The loading impedance shall be 16 ohm or greater. The output is short-circuit proof to GND.
Gain accuracy at 1 kHz: ±0.2 dB.
Frequency response re. 1 kHz: ±0.5 dB for 20 Hz < f < 16 kHz.
Reference conditions: The reference conditions for the instrument are as specified by IEC 61672-1 .
Environmental Conditions for Operation
Dimensions
Nor1261 Tripod adaptor Nor1261 is a “clip-on” tripod adaptor for use with 1/2″ Preamplifiers. Tripod attachment threads is 1/4″.
Nor1262 Tripod adaptor, adjustable “Clip-on” adjustable Tripod Adaptor for 1/2″ Preamplifiers. Both 3/8″ and 1/4″ tripod screws can be used.
Nor1335A Softbag Softbag in nylon with room for sound level meter Nor131 and Nor132, calibrator, and accessories. The bag is normally included in Nor131 and Nor132 deliveries.
Nor1434 windscreen, 90 mm Wind Shield for 1/2″ microphones/preamplifiers. Diameter 90mm.
Nor1451 windscreen, 60 mm Wind Shield for 1/2″ microphones/preamplifiers. Diameter 60mm.
Please click the button below to view the manufacturer’s product resources.
Please click the button below to view the manufacturer’s product videos.
Ask the team at Texcel how we can automate, inform, and empower your teams with our services.
Stay up to date on the latest industry news, technology and services from Texcel.
Terms of Use | Privacy Policy ©2020. All Rights Reserved | Website by Chilli
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |