Click and drag to rotate the image

GTM

Applications
  • Clients can schedule ‘Sleep’ modes when monitoring is not required.
  • Long battery life.
  • Large on board memory can record hundreds of waveforms and store thousands of events.
texcel-environmental-monitoring

At Texcel, our specialist team are passionate about delivering a product that continues to stay at the forefront of innovation and design. The GTM is one of the industry’s leading blast and vibration monitoring systems pioneered by Texcel. The ergonomic design of the GTM has been precision engineered to assist operations and compliance managers working within the Quarry, Mining, Construction and Civil Engineering industries. The GTM delivers unparalleled ease of operation, all contained within a lightweight package making transportation of this unit quick and easy.

 

Features include:

  • Clients can schedule ‘Sleep’ modes when monitoring is not required.
  • Long battery life.
  • Large on board memory can record hundreds of waveforms and store thousands of events.
Tech Specifications

Sensors

Input ranges can be configured by the user in T-Link.

The Low Frequency Geophone (2 Hz) has a maximum range of ±55.6 mm/s.

The high-frequency roll-off of the sensors (unless otherwise specified) is at 30% of the sampling rate. The roll-off frequencies shown below are for the standard 1000 Hz sample rate.

 

Geophone – 4.5 Hz High Range

RangeUp to ±111 mm/s (±4.37 in/s)
Resolution0.054 mm/s (0.0021 in/s)
Accuracy±5% @ 31.5 Hz
Bandwidth4.5 Hz to 300 Hz (-3 dB)
ThresholdUp to 111 mm/s (4.37 in/s) in steps of 0.054 mm/s (0.0021 in/s)

 

Geophone – 4.5 Hz High-Mid Range

RangeUp to ±55.6 mm/s (±2.19 in/s)
Resolution0.027 mm/s (0.0011 in/s)
Accuracy±5% @ 31.5 Hz
Bandwidth4.5 Hz to 300 Hz (-3 dB)
ThresholdUp to 55.6 mm/s (2.19 in/s) in steps of 0.027 mm/s (0.0011 in/s)

 

Geophone – 4.5 Hz Mid Range

RangeUp to ±27.8 mm/s (±1.09 in/s)
Resolution0.014 mm/s (0.00055 in/s)
Accuracy±5% @ 31.5 Hz
Bandwidth4.5 Hz to 300 Hz (-3 dB)
ThresholdUp to 27.8 mm/s (1.09 in/s) in steps of 0.014 mm/s (0.00055 in/s)

 

Geophone – 4.5 Hz Low-Mid Range

RangeUp to ±13.9 mm/s (±0.55 in/s)
Resolution0.0068 mm/s (0.00027 in/s)
Accuracy±5% @ 31.5 Hz
Bandwidth4.5 Hz to 300 Hz (-3 dB)
ThresholdUp to 13.9 mm/s (0.55 in/s) in steps of 0.0068 mm/s (0.00027 in/s)

 

Microphone

Range75 dBL to 138 dBL (±160 Pa)
Resolution0.12 Pa
Accuracy±5% @ 80 Hz
Bandwidth2.0 Hz to 300 Hz (-3 dB)

May be operated in “Peak Detect” mode, which meets the “Linear Peak Hold” or the “P” time-weighting characteristic as specified in AS1259.2 – 1990

ThresholdUp to 138 dBL (160 Pa) in steps of 0.12 Pa

 

Geophone – optional 2 Hz

RangeN/A High Range

Up to ±55.6 mm/s (±2.19 in/s)

Up to ±27.8 mm/s (±1.09 in/s)

Up to ±13.9 mm/s (±0.55 in/s)

ResolutionSame as 4.5 Hz geophone
AccuracySame as 4.5 Hz geophone
Bandwidth2.0 Hz to 300 Hz (-3 dB)
ThresholdSame as 4.5 Hz geophone

 

Triaxial Accelerometer

RangeUp to ±30 m/s² (~ ±3 g)

Up to ±15 m/s² (~ ±1.5 g)

Up to ±7.5 m/s² (~ ±0.75 g)

Up to ±3.75 m/s² (~ ±0.375 g)

Resolution0.0146 m/s² (0.00149 g) High Range
Accuracy±5% @ 31.5 Hz
Bandwidth0.4 Hz to 300 Hz (-3 dB)

0.4 Hz to 100 Hz (-3 dB) VDV Mode

ThresholdUp to 30 m/s² (~ 3 g) in steps of 0.0146 m/s² (0.00149 g) High Range

 

Cables

The maximum supported cable length for geophones, triaxial accelerometers and other active sensors is 100 m.  The maximum supported cable length for the microphone is 10 m.

 

Waveforms

Record modesSingle shot (Threshold, Auto), continuous logging
Sample ratesFrom 20 to 25 000 samples per second (sps) depending on settings
Record time128 to 131 072 points (0.128 to 131.072 seconds at 1000 sps)
Pre-trigger0% – 90 % in 10 % steps
Memory329 × 4 s waveforms at 1 000 samples per second, with 1 062 summaries

33 194 summaries with no waveforms

 

User Interface

DisplayLCD 16 characters × 2 lines, with backlight

Transparent waterproof cover on case

Keypad6 domed tactile keys + power switch
Connectors – top panelMini USB for PC communications
Charger
Connectors – sensorsMS12-10 for triaxial geophone

RO4-6 for microphone

 

Power Supply

BatteriesInternal rechargeable NiMH 4.3 A·h @ 9.6 V

336 hours continuous run time (depending on Settings)

ChargerInternational voltage (90 V to 260 V, 50 Hz to 60 Hz)

IEC320-C8 cable

Recharge TimeApprox. 6 hours

 

Physical

TemperatureOperating 0°C to 70°C (32°F to 158°F)

Display 0°C to 50°C (32°F to 122°F)

Dimensions191 mm × 129 mm × 80 mm
Weight1.6 kg
EnvironmentalSealed to IP65 when geophone and microphone connected, or caps in place

 

Additional Notes

  • Input ranges can be configured by the user in T-Link.
  • Resolution is 12 bits for all ranges.
  • Trigger threshold can be set up to full range.
  • The high-frequency roll-off of the sensors (unless otherwise specified) is at 30% of the sampling rate.
  • Some Sensor choices can limit available configuration and reporting options.
Downloads

Please click the button below to view the manufacturer’s product resources. 

Media

Please click the button below to view the manufacturer’s product videos.