Click and drag to rotate the image

AirMetER- AX

Applications
  • Industrial perimeter monitoring
  • Urban pollution monitoring
  • Park and outdoor air pollution monitoring
  • Public nuisance monitoring
  • Air pollution monitoring in construction sites

The AirMetER-AX is a compact, and easy to install Australian made air quality monitoring station. The modular design allows the unit to support 1-6 gas sensors, PM2.5, PM10, PM100, general weather conditions, noise and either vibration detection or black carbon measurements.

Housed in a weatherproof IP66 rated polycarbonate enclosure, the AirMetER-AX is ideal for continuous round the clock outdoor monitoring and has data logging capacity at a minimum of 365 days at one-minute intervals. It also has a built-in log and forward capability to capture 1 week of operation in the event of a network disruption.

Integrating seamlessly with Air-Met Scientific’s web-based portal for remote data access, this secure data portal enables users to access monitoring logs, set customisable alerts, manage monitoring reports and more. The web-service application is accessible on both desktop PC and mobile smart devices.

Tech Specifications

GENERAL

  • Power Requirement 12VDC
  • Rated Power 43W
  • Operating Temperature 0ºC to 50ºC
  • Operating Humidity 0 to 95% non-condensing
  • Operating Pressure 860 to 1100 hPa
  • Laser Module Operating Life 2 years (when operated below 40°C)
  • Datalogging (optional) 3 years of logs onboard with unique file name creation every 24 hours
  • Alarm Indicator (optional) Onboard dedicated alarm relay for all installed sensors

 

PARTICULATES MEASUREMENTS (specifications are based on 20°C and 860 – 1100 hPa conditions)

ParticulateRangeResolutionRelative Error
PM2.5 & PM100.999.9 µg/m30.1µg/m3Max of ± 15% and ±10µg/m3
PM1000.0-20.0mg/m31.0µg/mMax of ±20% and ± 30µg/m3

 

MEASUREMENTS (specification are based on 20°C and 760 mmHg conditions)
Gases

TypeRangeResolutionT90 Response (s)Min. Repeatable Detectable Level
CO (low range)0-30ppm1ppb< 3020ppb
CO (high range)0-300ppm1ppm< 25N/A
CO20-2000ppm1ppm<4015ppm
VOC (low range)0-40ppm1ppb<1015ppb
VOC (high range)0-200ppm1ppm<3N/A
SO20-10ppm1ppb<6020ppb
H2S0-20ppm1ppb<6020ppb
NO2  (low range)0-1000ppb1ppb<8020ppb
NO2 ( high range)0-20ppm0.1ppm<50N/A
O3  0-1000ppb1ppb<8020ppb
O20-25%VOL0.1% VOL<15N/A
NO0-5000ppb1ppb<4520ppb

 

NOISE

Integrated noise monitor using Sound Examiner

 

WEATHER SENSOR                                                                               

Integrated climate sensor for weather monitoring

  • Wind speed and direction
  • Air temperature
  • Relative humidity
  • Precipitation
  • Barometric air pressure
  • Class 2 Microphone
  • Range: 30 to 140 dBA
  • IEC61672-1 Standard and ANSI S1.4-1983

 

VIBRATION SENSOR

  • Sensor Type Triaxle piezoelectric
  • Typical Sensitivity 500mV/g
  • Transverse Sensitivity <5%
  • Frequency Response 4-1600Hz ± 10%
  • Typical Resonant Frequency 16kHz
  • Residual Noise 35µg RMS

 

SPECTRAL NOISE      

  • 3µg / √Hz @ 10Hz
  • 7μg / √Hz @ 100Hz
  • 5μg / √Hz @ 1000Hz
  • Standardised Events Detection

 

On Values or couple of values exceeding the tolerance curves

  • PPVjk/FDjk (DIN 4150-3 & “Circular”)
  • PCPVj/FDj (BS5228-4 & BS 7385-2
  • VpMaxjk (stopped)
  • VDVjk
  • Lpjk
  • i : value for a logging period τi
  • j : value for a logging period τj
  • k: value for an axis k

 

Available Standards

  • DIN 4150-3
  • BS 5228-2 (BS 7385-2)

 

BLACK CARBON SENSOR (FIVE WAVELENGTH)

Measurement Wavelengths              

880nm, 625nm, 528nm, 470nm & 375nm

Measurement Range          

  • Average 5μg BC/m3 for 24hrs @ 100ml/min (IR only mode)
  • Average 100μg BC/m3 for 3hrs @ 50ml/min (IR only mode)
  • Average 1mg BC/m3 for 15mins @ 50ml/min (IR only mode)

Measurement Resolution 0.001μg BC/m3

Operating Environment  5 ~ 40 °C operating, non-condensing

 

ENCLOSURE

  • Material Polycarbonate
  • Dimensions (mm) 500 H x 400 W x 210 D
  • Instrument Weight 15kg

Mounting Options               

  • Pole-mount kit supplied (recommended installation method)
  • Wall-mount – ~70mm offset required for dust inlet clearance

 

COMMUNICATION

  • PLC or SCADA Integration Serial RS232
  • FTP Upload Cellular, Ethernet or Wi-Fi

 

Accessories
  • TF-TRI-AL Tripod Mounting
  • AMS/200S/170B/15M/9C Remote Power System
  • LPF-60-12-AUP Power Supply (240V)
  • 121-5866 Pneumatic Silencer
  • 903-0886 Pump Filter
  • 002-3022-001 Water Stop Filter
  • KAM-SF9 NOx Filter (for Air-MetER AX-3)
Downloads

Please click the button below to view the manufacturer’s product resources. 

Media

Please click the button below to view the manufacturer’s product videos.